Primary
Application
Incorporating all
the proven features of the ESP Series, the ESP-Si family of hybrid
controllers is a prime example of making a good thing better. With
their slim line cabinets, ESP-Si controllers are as attractive to look
at as they are simple to use.
The ESP-Si Series
from Rain Bird. Simplicity at its finest.

ESP-Si
Features
- ESP:
Extra-Simple Programming
- Two
independent programs (A and B), with three start times each, allow
mixed irrigation applications in a single controller.
- "Flip
Strip" terminal strips permits valve wire hookup without screws.
- Wiring
skirt for clean looking, professional installation.
- System
water budgeting from 10 to 200% in 10% increments makes seasonal
adjustments quick and easy.
- Station
timing in 1-minute increments for precise watering requirements.
- Programmable
day-of-week watering schedule.
- Independent
dual programming.
- Easy-to-understand
AM/PM clock for quick reference.
- Self-prompting
alphanumeric liquid crystal display (LCD)
- 1A
external plug-in style transformer
- Slim,
indoor cabinet.
- Manual
start/advance capability for semi-automatic operation and system
testing.
- Mounting
screws provided for convenient installation
- Large,
high contrast LCD
- Remote
ready connector (station sequencing operation) compatible with Rain
Bird's RM-1R remote receiver.
Operating
Specifications
- Station
timing: 0-99 minutes (in 1-minute increments);
0-198 minutes with water budgeting
- Automatic
starts: 3 per program (6 per day when using dual program capability)
- Programming
schedule: 2-, 3-, or 5-day fixed cycle or 7-day variable cycle
- Water
budgeting: 10-200% in 10% increments
Electrical
Specifications
- Input
required: 117VAC @ 1A, 60Hz
- Output:
24VAC, 1A
- Overload
fuse: 1A (spare fuse provided in access cover)
- Surge
protection: Primary input side has built-in MOV (metal oxide varistor)
to protect microcircuitry; output side has one built-in MOV for each
valve station
- Battery
backup: A 3V lithium coin cell battery maintains program memory up to
several months and keeps timing accuracy during a power outage (battery
included with controller)
- Default
program: After prolonged power interruption, each station waters 10
minutes per cycle beginning 8 hours after power resumes –
once per day for the 7-day custom cycle or on the first day of the 2-,
3- or 5-day fixed cycle
- Multi-valve
station capacity: Up to two 24VAC, 7VA solenoid valves per station,
plus a master valve.
Dimensions
- Width:
7" (17,8 cm)
- Height:
8 1/4" (21,0 cm)
- Depth:
2 1/4" (5,7 cm)
Models
- ESP-4Si:
4 stations
- ESP-6Si:
6 stations
- ESP-8Si:
8 stations
Return To Top

Network LTC
Plus Field Hardware
- Unprecedented
power
- Ultimate value
- More protection

Features
- Exceptional
value with your choice of modules:
- 16 to 64 stations in 8-station
increments
- Standard or large-capacity terminal
block (accepts two 14-gauge wires)
- Standard or Gold Level
surge protection stations
- signal, pump and common input power
- Manual On/Off station switches
(optional)
- Sturdy plastic or painted
stainless-steel cabinetry
- Easy field installation and service:
- all componentry easily accessible and
in full view for fast troubleshooting
- straightforward terminal block
connections
- snap-in output modules
- guidepost aligns output module for
easy installation
- junction box eliminates need to bend
high-gauge power wire
- Operates as a stand-alone controller
(great for new construction) or under the management of a central
controller
- Dual-voltage power supply, 115 and 230 V
a.c.
- 24 V a.c. actuation
- Primary power isolation switch
- 16 independent programs, with up to 8
running simultaneously
- 14-day CALendar to 1- to 29-day
INTerval
- scheduling by program
- 0 to 3 repeats per program
- 0- to 59-minute soak time between
repeats
- up to 12 starts per program, per day
- exclusive Toro FlowSafe(TM) protects
flow-managed programs in the event of a central or wireline interruption
- Station run times from 1 minute to 8
hours and 59 minutes
- Global or independent program adjust at
the satellite
- Percent adjust by program (10 to 250%)
- Syringe %, allows 10-99% operating
adjustment
- Up to 2 non-irrigation (switch) programs
available with central software
- Non-volatile memory saves program data
for up to 10 years without power
- Pump & Common control module with
standard surge protection
- Manual operation by program (normal or
syringe) independent station or multiple stations (up to 6)
- Patented Toro Hot Post for easy valve
activation and identification
Electrical Specifications
- Input power:
- 115/230 V a.c., 50/60 Hz
- 0.183 amps @ 115 V a.c., 60 Hz (no
load)
- 872 amps @ 115 V a.c., 60 Hz (maximum
load)
- 0.181 amps @ 230 V a.c., 50 Hz (no
load)
- 0.50 amps @ 230 V a.c., 50 Hz
(maximum load)
- Station output power:
- 24 V a.c.
- 0.75 amps (18 VA) per station
- 3.15 amps (76 VA) total
- Station draw:
- up to 3 solenoids per station
- 12 solenoids may operate
simultaneously
Mechanical Specifications
- Dimensions:
- Stainless-Steel Pedestal: 13" W x 35
3/4" H x 13" D (330mm W x 908mm H x 330mm D)
- Plastic Pedestal: 16" W x 39" H x 13"
D (330mm W x 908mm H x 330mm D)
- Plastic Pedestal: 16" W x 39" h x 15"
D (405mm W x 990mm H x 381mm D)
Return To Top

Four program
master control or independent station programming
Flow
monitoring provides regulation and shutdown for out of tolerance flows
Heavy duty input and output surge protection
Four start times and four soak cycles per program
Selectable stacking or concurrent operation for each program
Pump Start or Master Valve assignable by station
Versatile watering schedules, Everyday, Select Days, 14 day calendar
Odd or even days
Specified dates for injection of fertilizer
Interval 1 to 365 days
One minute to 24 hour station timing
Seasonal timing adjustment by program 5-300%
Global delay between stations starts, adjustable from one minute to one
hour
Safety delay for master valve/pump shutdown
Sensor to detect "short" or "open" circuits
Rain sensor switch input
Daily "no water" window
Special Events to omit watering by calendar date
Manual program or station start
Test program; one to 10 minutes
Security code, 2 levels
Self diagnostics
Automatic daylight savings time and leap year adjustment
Non-volatile memory and real time clock retain all programming and
keeps date and time during power loss
Easy to read backlit LCD for clear viewing
Return To Top
Back to Reinder's Home Page
|